You are here: Products > Cables & Wires

Cathodic Protection Cable - HMW/PE

High Molecular Weight Polyethylene

Single Conductor, Copper 600 volts

Application

Direct earth burial for cathodic protection of pipelines, oil tanks, steel piles, well casings, marinecraft and other metallic structures.

Standards

  1. Standard copper conductors conform to ASTM specifications B-8 and B-3 latest edition.
  2. Conforms to ASTM D-1248, type 1 Class C, Category 5, Grade E-5, E-4 and ICEA S61 - 402, part 6 paragraph 6, 11, 4a

Identification

Ink surface printed with "Conductor Size, KALAS MFG., HMW/PE CATHODIC PROTECTION CABLE"

Guage Stranding Insulation Thickness Nom O.D. Std. Ft./Reel Approx. Ship. Lbs/M'
10  7/.0358  .100  .316  5,000  75
8  7/.0486  .110  .366  5,000  95
6  7/.0612  .110  .404  4,000  135
4  7/.0772  .110  .451  3,000  190
2  7/.0974  .110  .512  2,500  225
1  19/.0664  .125  .584  2,500  360
1/0  19/.0745  .125  .623  2,500  435
2/0  19/.0837  .125  .669  2,500  540
3/0  19/.0940  .125  .720  1,750  670
4/0  19/.1055  .125  .778  1,500  800

 